Complete Blood Count (CBC) report format

Automated haemogram with differential count and red cell indices. Indices are calculated from the measured values. Every field below is yours to edit once the library is in your catalogue.

How this format is set up

Test code
CBC
Department
Haematology
Sample
Whole Blood (EDTA)
Method
Automated Cell Counter
Turnaround
2 h

Parameters and reference ranges

18 lines print on the report, and 5 of them are worked out by the system from the values beside them.

Reference ranges are shown as they ship. The engine picks the most specific range that matches the patient in front of you.
ParameterUnitDecimal placesReference ranges
HaemoglobinHGBg/dL1
  • Male 13 – 17 critical < 7 or > 20
  • Female 12 – 15 critical < 7 or > 20
  • Up to 12 y 11.5 – 15.5 critical < 7
RBC CountRBCmillion/µL2
  • Male 4.5 – 5.5
  • Female 3.8 – 4.8
PCV / HaematocritPCV%1
  • Male 40 – 50
  • Female 36 – 46
MCVMCVcalculated(PCV / RBC) * 10fL1
  • All patients 83 – 101
MCHMCHcalculated(HGB / RBC) * 10pg1
  • All patients 27 – 32
MCHCMCHCcalculated(HGB / PCV) * 100g/dL1
  • All patients 31.5 – 34.5
RDW-CVRDW%1
  • All patients 11.6 – 14
Total Leucocyte Count (TLC)WBC/µL0
  • All patients 4000 – 11000 critical < 2000 or > 30000
NeutrophilsNEUT%0
  • All patients 40 – 80
LymphocytesLYMPH%0
  • All patients 20 – 40
EosinophilsEOS%0
  • All patients 1 – 6
MonocytesMONO%0
  • All patients 2 – 10
BasophilsBASO%0
  • All patients 0 – 2
Absolute Neutrophil CountANCcalculated(WBC * NEUT) / 100/µL0
  • All patients 2000 – 7000 critical < 500
Absolute Lymphocyte CountALCcalculated(WBC * LYMPH) / 100/µL0
  • All patients 1000 – 3000
Platelet CountPLT/µL0
  • All patients 150000 – 410000 critical < 20000 or > 1000000
MPVMPVfL1
  • All patients 6.5 – 12
RBC MorphologyRBC_MORPHNot applicableNot applicableReported without a fixed range

See a rendered sample report built from this format, with fictional patient data.

Included in these panels

Ordering one of these creates this format along with the rest of its member tests, on one order and one bill.

How this format gets into your lab

One click installs the shipped library into your own catalogue. From that moment the format is yours: rename a parameter, change a unit or a decimal place, rewrite a reference range, add an age band, or delete a line your lab does not report. Nothing here is locked, and nothing is fetched from us at print time.

Prices, sample types and methods sit on the same record, so the front desk can bill this test as soon as the library is installed.

The install endpoint that writes the library into one lab’s catalogue.

Reference ranges follow common Indian laboratory practice; review against your own method and instrument before going live.

Set up your lab this afternoon.

Create your organisation, add your tests, print the first barcode. If you would rather see it first, ask for a walkthrough.

Start freeBook a demo