Semen Analysis report format

Reference values follow the WHO 6th edition lower reference limits. Every field below is yours to edit once the library is in your catalogue.

Test code
SEMEN
Sample
Semen
Method
Microscopy
Turnaround
3 h

Parameters and reference ranges

16 lines print on the report, and 1 of them are worked out by the system from the values beside them.

Semen Analysis parameters with their units, decimal places and reference ranges.
Days of AbstinenceABSTINENCEUnitdaysDecimals0
  • All patients2 – 7 days (WHO)
VolumeVOLUMEUnitmLDecimals1
  • All patients≥ 1.4
AppearanceS_APPEARANCE3 picklist optionsUnitNot applicableDecimalsNot applicableReported without a fixed range
Liquefaction TimeLIQUEFACTIONUnitminutesDecimals0
  • All patients< 30 min
pHS_PHUnitNot applicableDecimals1
  • All patients7.2 – 8.0
Sperm ConcentrationSPERM_COUNTUnitmillion/mLDecimals1
  • All patients≥ 16
Total Sperm NumberSPERM_TOTALCalculatedSPERM_COUNT * VOLUMEUnitmillionDecimals1
  • All patients≥ 39
Total MotilityMOTILITY_TOTALUnit%Decimals0
  • All patients≥ 42
Progressive MotilityMOTILITY_PROGUnit%Decimals0
  • All patients≥ 30
Non-progressive MotilityMOTILITY_NONPROGUnit%Decimals0Reported without a fixed range
ImmotileMOTILITY_IMMOTILEUnit%Decimals0Reported without a fixed range
Vitality (live sperm)VITALITYUnit%Decimals0
  • All patients≥ 54
Normal MorphologyMORPHOLOGYUnit%Decimals0
  • All patients≥ 4
AgglutinationAGGLUTINATION2 picklist optionsUnitNot applicableDecimalsNot applicableReported without a fixed range
Pus CellsS_PUS_CELLSUnit/hpfDecimals0
  • All patients0 – 5 /hpf
ImpressionS_IMPUnitNot applicableDecimalsNot applicableReported without a fixed range

Reference ranges are shown as they ship. The engine picks the most specific range that matches the patient in front of you.

How this format gets into your lab

One click installs the shipped library into your own catalogue. From that moment the format is yours: rename a parameter, change a unit or a decimal place, rewrite a reference range, add an age band, or delete a line your lab does not report. Nothing here is locked, and nothing is fetched from us at print time.

Prices, sample types and methods sit on the same record, so the front desk can bill this test as soon as the library is installed.

The library is copied into your own catalogue, so later changes to it never alter yours.

Set up your lab this afternoon.

Create your organisation, add your tests, print the first barcode. If you would rather see it first, ask for a walkthrough.

Start 30-day free trialBook a demo